RSS

Blog posts tagged with 'door closer adjustment'

ADA Door Clearance: Widths, Maneuvering Space and Hardware Rules

Quick Summary

Key points

  • ADA door clearance is not one number. It is a set of linked requirements covering clear width, floor space either side of the door, opening force, closing speed and the height and shape of the hardware.
  • The headline figure is 32 inches of clear width, measured with the door open 90 degrees, from the face of the door to the opposite stop. The door leaf itself has to be wider than that.
  • Opening force on an interior hinged door is capped at 5 pounds. That single number is what sends most facilities back to the door closer.
  • Closing speed is a minimum, not a maximum. The door has to take at least 5 seconds to travel from 90 degrees down to 12 degrees.
  • Most non compliant openings are fixed with parts rather than with a new door: a correctly sized closer, a different arm, a lever instead of a knob, or a low energy operator.
The five measurements that decide whether an opening is accessible
RequirementWhat it governsWhere it bites
Clear widthThe usable gap when the door stands open 90 degreesNarrow leaves, projecting hardware, oversized stops
Maneuvering clearanceFloor space in front of and beside the doorCorridors, vestibules, doors tight to a side wall
Opening forceEffort needed to start the door movingOversized or over tensioned door closers
Closing speedTime the door takes to swing shutSweep valve set too fast, worn closer
Hardware height and shapeWhere the handle sits and how it is grippedKnobs, thumbturns, high mounted trim

Most people meet ADA door clearance as a line on an inspection report rather than as a design decision. Somebody measures an opening, writes down a number that is short by an inch, and the building owner is left guessing whether that means a new door frame or a different part.

In practice the answer is usually a part. This guide walks through each clearance requirement in turn, explains what is actually being measured, and shows which piece of door hardware controls it, so you can work out whether the opening needs a carpenter or a box from the shelf.

What Does ADA Door Clearance Actually Mean?

ADA door clearance is shorthand for a group of requirements in the 2010 ADA Standards for Accessible Design that together make a doorway usable by someone with limited mobility, limited reach or limited grip strength.

The requirements fall into two families. The first is about space: how wide the opening is and how much floor there is to maneuver on either side. The second is about effort: how hard the door is to pull, how fast it comes back, and whether the handle can be worked with a closed fist.

The split matters because the two families have very different remedies. Space problems are building problems. Effort problems are hardware problems, and hardware problems are the ones you can usually solve without touching the structure.

Which doors have to comply?

Accessible routes are the trigger. Doors on an accessible route into and through a building have to meet these requirements, which in most commercial buildings means the main entrance, corridor doors, restroom doors and the doors to any space the public or employees are expected to reach.

Doors that are not on an accessible route, such as a door to a space entered only for maintenance, are treated differently. Local code and the building official have the final word, so confirm the scope before you start replacing parts.

How Much Clear Width Does an Accessible Door Need?

The standard calls for a minimum of 32 inches of clear width. The measurement is taken with the door open 90 degrees, from the face of the door to the opposite stop. It is not the width of the frame and it is not the width of the leaf.

That distinction catches people out. A 36 inch leaf does not give you a 36 inch opening, because the thickness of the door and the depth of the stop both eat into the gap. A 32 inch leaf will not pass at all.

Hardware can eat into it too. Door mounted projections between 34 and 80 inches above the floor are limited to 4 inches of projection into the opening, which is why surface mounted exit device chassis and bulky pull trim get looked at closely on narrow leaves.

Doors in series

Vestibules have their own rule. Where two doors are in series, there has to be at least 48 inches between them, measured clear of the swing of any door that opens into the space. A tight vestibule with two inward swinging doors is one of the most common failures on older buildings.

What Maneuvering Clearance Is Required on Each Side of the Door?

Clear width gets a person through the gap. Maneuvering clearance gives them the floor space to position a wheelchair, reach the handle and pull the door without being pushed backwards by it.

The required space changes with the direction of approach and with which side of the door you are on. The pull side always needs more room than the push side, because the user has to retreat as the door comes towards them.

Swinging door maneuvering clearance, front approach
Side of doorSpace beyond the latchDepth of clear floor space
Pull side18 inches minimum60 inches minimum
Push side, no closer and no latchNone required48 inches minimum
Push side, with both closer and latch12 inches minimum48 inches minimum

That bottom row is the one that surprises facilities teams. Adding a door closer to a door that already has a latch changes the maneuvering clearance requirement on the push side. A closer is not a neutral addition to an opening.

Hinge side and latch side approaches have their own figures, and they are more generous in depth because the user is coming at the door from an angle. If an opening fails on approach geometry and the walls cannot move, a power operator is usually the way out.

How Much Force Can It Take to Open the Door?

Interior hinged doors are limited to 5 pounds of opening force. Sliding and folding doors carry the same 5 pound limit. The figure applies to the effort needed to get the door moving and to keep it swinging, not to the effort needed to release a latch.

Exterior doors are the exception people misquote. The ADA Standards do not set a maximum opening force for exterior hinged doors, which is why wind load and stack pressure are handled through local code and through the choice of closer rather than through a single national number.

Fire doors are the other exception. A fire rated door has to latch positively every time, which takes spring power, so the standard allows the minimum opening force permitted by the authority having jurisdiction rather than a flat 5 pounds.

LCN 4040XP surface door closer used to control ADA door clearance opening force
Opening force is a closer problem before it is a door problem. A heavy duty surface closer such as the LCN 4040XP has adjustable spring power, so the same unit can be dialled down on an interior door and wound up on an exterior one.

Why the closer is almost always the cause

A door closer works by compressing a spring as the door opens. The stronger the spring setting, the harder the pull. Facilities teams raise the spring power to make a door latch reliably, then fail the opening force test without realising the two are connected.

The honest fix is rarely to weaken the spring until the door stops latching. It is to reduce the resistance the spring is fighting: free up a binding hinge, correct a dragging sweep, fix a strike that the latch is scraping into, and only then reset the spring.

How Slowly Does the Door Have to Close?

Closing speed is specified as a minimum time, which trips people up because every other door requirement is a maximum. The door has to take at least 5 seconds to travel from 90 degrees open down to 12 degrees from the latch.

Where spring hinges are used instead of a closer, the equivalent requirement is that the door takes at least 1.5 seconds to swing from 70 degrees to the closed position.

On a conventional closer this is the sweep valve, the adjustment that governs the main part of the swing. Latch speed, the short burst at the end, is a separate valve and is not what the 5 second measurement is testing.

Which closer adjustment affects which requirement
AdjustmentPart of the swing it controlsAccessibility requirement it affects
Spring powerResistance throughout the opening swingOpening force
Sweep valveFrom roughly 90 degrees to about 15 degreesClosing speed
Latch valveThe final few degrees into the strikePositive latching, not closing speed
BackcheckCushioning near the fully open positionProtects the door and frame, no direct requirement
Delayed actionHolds the door near open before the sweep beginsHelpful where a user needs more time to clear the opening

If you are working through these valves on a specific unit, our guide to adjusting a commercial door closer walks through the order to do them in, and the closer sizing guide covers choosing the right size in the first place.

What Height Does the Door Hardware Have to Be?

Operable hardware has to sit between 34 and 48 inches above the finished floor. That band covers levers, panic bar touchpads, thumbturns and anything else a user has to work to get through the door.

Most commercial hardware lands inside the band by default, because standard lock heights put a lever at around 38 to 40 inches. The parts that drift outside it are additions: a surface bolt near the top of the door, a secondary deadbolt fitted high, or a thumbturn mounted above the main lock.

On a pair of doors, check the inactive leaf as well. Flush bolts at the head of the inactive leaf are not operable parts in the accessibility sense, but any hardware a user is expected to work to pass through the opening is.

Which Types of Door Hardware Meet the Operable Parts Rule?

The rule is written in terms of what the user must not have to do. Hardware must be operable with one hand and must not require tight grasping, tight pinching or twisting of the wrist. Operating force is capped at 5 pounds.

That wording is what rules out the round knob. A knob cannot be turned without grasping and twisting, and no amount of adjustment changes that. It also rules out small thumbturns that need a pinch grip, and tight recessed pulls.

Common hardware against the operable parts test
Hardware typeMeets the one hand, no twisting testNotes
Lever handleYesOperable with a closed fist or a forearm
Round knobNoRequires grasping and twisting
Panic bar touchpad or crossbarYesOperates with a push anywhere along the bar
Push or pull plateYesNo latch operation involved
Small thumbturnUsually noPinch grip, check the size and shape of the turn
Key operated lockNot countedLocks used only for security are treated separately
Falcon Q330-271 T Series spring cage kit used to restore lever return on an accessible door
A lever that sags stops returning to horizontal and starts catching on clothing. On Falcon T Series locks the spring cage is a serviceable part, so a drooping lever is a repair rather than a lockset replacement.

Levers that have stopped behaving

A compliant lever that has worn is a quiet failure. Once the return spring weakens the lever droops, and a drooping lever is both a snag hazard and a sign the latch is no longer being fully retracted. Spring cages and lever kits are stocked as individual parts for exactly this reason.

When Does a Power Operator Become the Only Practical Answer?

Three situations push an opening towards a powered solution. The maneuvering clearance is not there and the walls cannot move. The door is a fire door that has to latch, so the spring power cannot come down. Or the door is an exterior door fighting wind and stack pressure.

Low energy operators are the type used on accessible entrances. They open the door slowly, under limited force, and only when a person deliberately activates them by pressing a plate or waving at a sensor. They are covered by ANSI/BHMA A156.19, which sets the opening and closing timings.

Detex AO19-1 low energy automatic door operator for an accessible single door
A low energy operator takes the opening force question off the table. The Detex AO19-1 drives a single door and still controls it on the way closed, so it replaces the closer rather than sitting alongside one.

The operator is only half the decision. The activation device is a separate choice, and it has its own reach and height requirements because a user has to be able to work it from a clear floor space that does not sit in the path of the opening door.

LCN 8310-866 bollard post actuator for activating an accessible automatic door
Where there is no wall in the right place, a bollard post puts the actuator where the user can reach it and keeps it out of the door swing. The post and the actuator head are ordered as separate parts.

For the whole powered opening, including sensors and control boxes, see our commercial door operators guide and the door operator parts guide.

What About Thresholds and the Bottom of the Door?

Thresholds at doorways are limited to half an inch in height. Anything above a quarter inch has to be beveled, at a slope no steeper than one in two, so a wheel can ride up rather than stop against a square edge.

The push side of the door has its own rule. The bottom 10 inches has to present a smooth surface across the full width, so a footrest can push the door open without catching. Projecting kick plate edges and applied mouldings in that zone are what fail this one.

Both of these are easy to break during a repair. A new sweep that stands proud, or a kick plate fitted with raised fixings, can put a previously compliant door outside the rule without anyone noticing.

Which Parts Do You Actually Change to Bring an Opening Into Compliance?

Working from the most common finding to the least, the fix list is short and almost all of it is parts rather than construction.

Typical finding and the part that resolves it
Finding on the reportUsual causeWhat you change
Opening force too highCloser spring wound up to force latchingCorrect the binding first, then reset spring power, or fit a correctly sized closer
Door closes too fastSweep valve open too far, or a tired closerSweep adjustment, or a cylinder assembly if the closer is leaking
Knob instead of leverOriginal hardware predates the requirementLever trim or a lever lockset in the same function
Hardware mounted too highAdded deadbolt or surface boltRelocate, or consolidate the function into the main lock
Maneuvering clearance shortWall position, cannot be changedLow energy operator and an actuator the user can reach
Threshold too tall or square edgedFloor build up over timeBeveled threshold within the half inch limit

Before ordering anything, confirm what is already on the door. The closer body, the arm and the mounting plate are separate line items, and an arm change alone sometimes solves a force problem that looks like it needs a new closer. Our door closer parts section and the guide to the four types of commercial door closer cover how those pieces fit together.

Where the opening is also fire rated, check the two requirement sets together rather than one after the other. Our commercial door fire rating guide and the ANSI and BHMA standards guide explain where the grading and labelling requirements sit alongside accessibility.

About the Author

Security Parts has supplied repair parts for commercial door hardware since 2001, covering Von Duprin, LCN, Schlage, Falcon, Detex and Adams Rite at the component level. Our diagram based lookup exists so a technician can confirm a part before ordering it. This guide was written by the Security Parts team from supplier documentation and the questions our customers bring us.

If you have a measurement that is failing and you know the hardware on the door, start with the parts by product type index, or contact us with the model number and we will confirm the part before you order.